Ultrasonic Level Sensor

Teflon level sensor tank level meter
IP68 water tank level meter
24VDC Ultrasonic level meter
OEM service level instrument
Non-contact Ultrasonic Level Meter Ultrasonic water level meter
Free after-service water level meter

Category:

Description

The sensor of the meter pulses in the direction of the product surface. There, they are reflected back and received by the sensor.The meter measures the time t between pulse transmission and reception. The meter uses the time t (and the velocity of sound) to calculate the distance D between the sensor membrane and the product surface:

D = c *t/2. As the device knows the empty distance H from a user entry, it can calculate the level as follows: L= H – D

ultrasonic level sensor

B:Blanking distance D:distance value L:level value

H: installation height F:level span

Two Working Mode

The instrument has two working mode: running state and operating state.

Press the two keys SEL and MOV to change within two different modes.

In running mode, green lamp will keep on lighting. In programming mode, green lamp will flash.

On measuring mode, level meter will carry out normal measuring, at this time, press the SEL key, displayed location value, empty value and temperature will be alternated.

ultrasonic level sensor ultrasonic level sensor

Instrument installation

Reasonable instrument installation is the key to its reliable work.

Level meter installed on the top of the container,Probe surface vertical point to liquid level. If is airtight container,should be adopted flange installation.Other conditions can use bracket installation.

Flange installation should be according to the thread sizes make the flange of the level meter.20m,30m type has directly equipped with the flange.

General Instruction

1. The temperature of the process may not exceed 75℃,and the pressure may not exceed ±0.1 MPa.

2. For exposed or sunny locations a protective hood is recommended.

3.Level meter must be some distance from the tank wall.

4.There’s beam angle when Energy transducer radiate ultrasonic pulse. From energy transducer lower edge to measured medium,please avoid A.B obstacle in the radiation region of ultrasonic wave beam.(For example:human ladder;level switch etc).

5.Please make sure ultrasonic beam angle can not intersect with feed stream.

6.Please make sure the max material level can not enter into measuring blind area.

7.Please try to make sure the energy transducer radiate direction vertical to the medium level.

FAQ

1.Q: Are you a trading company or a manufacturer?

A:We are a manufacturer, which has 12 years of experience in this industry.

2.Q:How long is your warranty time ?

A:Two years(Calculated from the equipment arrives the customer’s side.).After this period we will support you when needed.You will be welcome to contact us with any problem may happened.

3.Q:Will you send engineers to install flow instrument?

A:Yes,but at an extra cost payable by the customer.

5.Q:Do you have some foreign customers using your equipment?

A:Yes,we have.our company has established business relationships with customers from all over the world

Technical Parameters

Reviews

There are no reviews yet.

Be the first to review “Ultrasonic Level Sensor”

Your email address will not be published. Required fields are marked *

Shopping Cart

Product Enquiry